Home > Exhibition > Content

Operation and maintenance regulations for inverted vertical drawing machine

Aug 04, 2018

For the user, the inverted wire drawing machine needs to be operated according to the specifications before, during and after use. In daily work, when the drawing operation is completed, proper maintenance of the inverted wire drawing machine is also required.

 

About the operation of the inverted wire drawing machine:

After the end of the production operation, the inverted wire drawing machine equipment should be closed according to the normal procedure. After the work is completed, the routine cleaning and maintenance should be carried out. Pay attention to maintaining the environmental sanitation of the machine and the surrounding area, and carry out on-site cleaning and finishing according to the ā€œ6Sā€ standard. If the operator needs to leave the job or suddenly lose power, turn off all power to avoid accidents.

 

The maintenance regulations for the inverted wire drawing machine include:

1. Regularly check the wear condition of the wire drawing wheel and the pressure wheel, and whether the connecting bolts of various parts are loose or loose.

2. It is required to check the oil level of the lubricating oil in the gearbox of the inverted wire drawing machine daily and add the lubricating oil regularly.

3. Check whether the electrical line contact of the inverted wire drawing machine is good, whether the wire is aging or not, and clean the electrical box.